Docs › Tutorials

Two-stage gas compression

Compress associated gas from 30 to 600 psia in two stages, with coolers and scrubbers. Read the discharge temperature, the power and the condensate that drops out.

About 30 minutes. Skills: compressor, cooler, scrubbers, power. In the app: Start page › Oil & gas exercises › Two-stage gas compression. The finished case is Gas compression under Oil & gas starter cases.

The finished gas compression case: suction scrubber, two compressors, two coolers and two more scrubbers

1. Start a new case and set up the fluid

Tap New case. Add the nine components below, keep Peng-Robinson, and tap Simulation.

ComponentMole fractionComponentMole fraction
Nitrogen0.01i-Butane0.03
CO20.02n-Butane0.045
Methane0.605n-Pentane0.025
Ethane0.14n-Hexane0.015
Propane0.11

2. Add the LP gas

Material Stream LP Gas: 100 °F, 30 psia, 549 lbmole/hr (5 MMSCFD), with the mole fractions above.

3. Suction scrubber and first stage

  1. Separator V-100 on LP Gas, with outlets Suction 1 (vapour) and Drain 1 (liquid). A scrubber protects the compressor from liquid slugs even when the gas is dry.
  2. Compressor K-100 from Suction 1 to Discharge 1. Give Discharge 1 a pressure of 140 psia. Keep the 75 % efficiency.

4. Intercooler and second stage

  1. Cooler E-100 on Discharge 1, outlet Cooled 1: 120 °F outlet temperature and a 5 psi pressure drop (Delta P on Parameters).
  2. Separator V-101 on Cooled 1, outlets Suction 2 and Drain 2.
  3. Compressor K-101 from Suction 2 to Discharge 2 at 605 psia.

5. Aftercooler and discharge scrubber

Cooler E-101 on Discharge 2, outlet Cooled 2: 120 °F, 5 psi drop. Separator V-102 with outlets Export Gas and Drain 3. The export gas leaves at 600 psia.

6. Questions

  1. First-stage discharge. How hot is Discharge 1? Compression heats gas, which is why each stage needs a cooler before the next.
  2. Condensate. How much liquid collects in Drain 3?

Expected results

ObjectValueResult
Discharge 1Temperature289.5 °F
K-100Power546.6 hp
E-100Duty1320031 Btu/hr
Discharge 2Temperature313.1 °F
K-101Power525.0 hp
E-101Duty1840846 Btu/hr
Cooled 2Vapour fraction0.9429
Export GasMolar flow517.6 lbmole/hr
Drain 3Molar flow31.4 lbmole/hr

V-100 and V-101 see vapour only, so Drain 1 and Drain 2 carry no flow.

Try next

  • Change the interstage pressure from 140 psia and compare the total power of K-100 and K-101.
  • Switch K-100 to a polytropic efficiency basis and compare the results.
  • Continue with Propane refrigeration loop.