Docs › Tutorials

JT dew point control

Take natural gas liquids out of rich gas with a gas/gas exchanger, a JT valve and a cold separator. The cold gas pre-cools the feed, so the flowsheet has a loop the solver closes on its own.

About 30 minutes. Skills: heat exchanger, recycle loop, JT valve, dew point. In the app: Start page › Oil & gas exercises › JT dew point control. The finished case is under Oil & gas starter cases.

The finished JT dew point control case: inlet separator, Gas/Gas exchanger, JT Valve and LTS

1. Start a new case and set up the fluid

Tap New case. Add the eleven components below, keep Peng-Robinson, and tap Simulation.

ComponentMole fractionComponentMole fraction
Nitrogen0.01n-Butane0.02
CO20.02i-Pentane0.008
Methane0.78n-Pentane0.007
Ethane0.08n-Hexane0.005
Propane0.045n-Heptane0.01
i-Butane0.015

2. Rich gas feed

Material Stream Rich Gas: 100 °F, 1200 psia, 2196 lbmole/hr (20 MMSCFD), with the mole fractions above.

3. Inlet separator

Separator Inlet Sep on Rich Gas, outlets Inlet Gas and Inlet Liquid.

4. Exchanger, JT valve and cold separator

  1. Heat Exchanger Gas/Gas: Tube in Inlet Gas, Tube out Cooled Gas. On Parameters, set a 5 psi drop on each side (Tube side and Shell side Delta P).
  2. Valve JT Valve from Cooled Gas to JT Outlet at 700 psia.
  3. Separator LTS on JT Outlet, outlets Cold Gas and NGL.
  4. Back on the exchanger, connect Cold Gas as Shell in and a new stream Sales Gas as Shell out.

Cold gas from the LTS now pre-cools the incoming gas, so the flowsheet has a loop. You do not need a Recycle: the solver tears the loop and iterates on its own.

5. Exchanger approach

  1. Open the exchanger's Specs page and tap Add.
  2. Choose the type Delta Temp, with the tube inlet (Inlet Gas, the hot inlet) as Stream (+) and the shell outlet (Sales Gas, the cold outlet) as Stream (−).
  3. Enter a Spec Value of 10 °F and tap Add. Everything solves.

6. Questions

  1. JT cooling. What is the temperature of JT Outlet? Compare it with Cooled Gas. Expansion with no heat exchange cools a gas: roughly 5 to 7 °F for every 100 psi here.
  2. NGL recovered. What is the molar flow of NGL from the LTS?

Expected results

StreamValueResult
Rich GasVapour fraction0.9592
Inlet LiquidMolar flow89.6 lbmole/hr
Cooled GasTemperature68.0 °F
JT OutletTemperature41.5 °F
JT OutletVapour fraction0.9515
NGLMolar flow102.1 lbmole/hr
Sales GasTemperature90.0 °F
Sales GasMolar flow2004.3 lbmole/hr

Taking out the NGL lowers the gas's hydrocarbon dew point at 800 psia from about 149 °F to about 41 °F.

Try next

  • Use an Adjust to find the JT valve pressure that brings the cold separator to 30 °F: see Adjust.
  • Open the Gas/Gas exchanger's Performance tab and read its duty, LMTD and minimum approach.