JT dew point control
Take natural gas liquids out of rich gas with a gas/gas exchanger, a JT valve and a cold separator. The cold gas pre-cools the feed, so the flowsheet has a loop the solver closes on its own.
About 30 minutes. Skills: heat exchanger, recycle loop, JT valve, dew point. In the app: Start page › Oil & gas exercises › JT dew point control. The finished case is under Oil & gas starter cases.

1. Start a new case and set up the fluid
Tap New case. Add the eleven components below, keep Peng-Robinson, and tap Simulation.
| Component | Mole fraction | Component | Mole fraction |
|---|---|---|---|
| Nitrogen | 0.01 | n-Butane | 0.02 |
| CO2 | 0.02 | i-Pentane | 0.008 |
| Methane | 0.78 | n-Pentane | 0.007 |
| Ethane | 0.08 | n-Hexane | 0.005 |
| Propane | 0.045 | n-Heptane | 0.01 |
| i-Butane | 0.015 |
2. Rich gas feed
Material Stream Rich Gas: 100 °F, 1200 psia, 2196 lbmole/hr (20 MMSCFD), with the mole fractions above.
3. Inlet separator
Separator Inlet Sep on Rich Gas, outlets Inlet Gas and Inlet Liquid.
4. Exchanger, JT valve and cold separator
- Heat Exchanger Gas/Gas: Tube in Inlet Gas, Tube out Cooled Gas. On Parameters, set a 5 psi drop on each side (Tube side and Shell side Delta P).
- Valve JT Valve from Cooled Gas to JT Outlet at 700 psia.
- Separator LTS on JT Outlet, outlets Cold Gas and NGL.
- Back on the exchanger, connect Cold Gas as Shell in and a new stream Sales Gas as Shell out.
Cold gas from the LTS now pre-cools the incoming gas, so the flowsheet has a loop. You do not need a Recycle: the solver tears the loop and iterates on its own.
5. Exchanger approach
- Open the exchanger's Specs page and tap Add.
- Choose the type Delta Temp, with the tube inlet (Inlet Gas, the hot inlet) as Stream (+) and the shell outlet (Sales Gas, the cold outlet) as Stream (−).
- Enter a Spec Value of 10 °F and tap Add. Everything solves.
6. Questions
- JT cooling. What is the temperature of JT Outlet? Compare it with Cooled Gas. Expansion with no heat exchange cools a gas: roughly 5 to 7 °F for every 100 psi here.
- NGL recovered. What is the molar flow of NGL from the LTS?
Expected results
| Stream | Value | Result |
|---|---|---|
| Rich Gas | Vapour fraction | 0.9592 |
| Inlet Liquid | Molar flow | 89.6 lbmole/hr |
| Cooled Gas | Temperature | 68.0 °F |
| JT Outlet | Temperature | 41.5 °F |
| JT Outlet | Vapour fraction | 0.9515 |
| NGL | Molar flow | 102.1 lbmole/hr |
| Sales Gas | Temperature | 90.0 °F |
| Sales Gas | Molar flow | 2004.3 lbmole/hr |
Taking out the NGL lowers the gas's hydrocarbon dew point at 800 psia from about 149 °F to about 41 °F.
Try next
- Use an Adjust to find the JT valve pressure that brings the cold separator to 30 °F: see Adjust.
- Open the Gas/Gas exchanger's Performance tab and read its duty, LMTD and minimum approach.