Docs › Tutorials

Crude oil pipeline

Pump stabilised crude into a 30 km, 10-inch line that climbs 60 m, and find the arrival pressure and pump power. Introduces mass fractions, the pump and the pipe segment.

About 25 minutes. Skills: mass fractions, pump, pipe segment, hydraulics. In the app: Start page › Oil & gas exercises › Crude oil pipeline. The finished case is Crude pipeline under Oil & gas starter cases.

The finished crude pipeline case: pump P-100 and pipe segment PIPE-100

1. Start a new case and set up the fluid

Tap New case. Add the eight components below, keep Peng-Robinson, and tap Simulation.

ComponentMass fractionComponentMass fraction
n-Pentane0.03n-Decane0.18
n-Hexane0.06n-C12 (n-dodecane)0.16
n-Heptane0.10n-C16 (n-hexadecane)0.20
n-Octane0.12n-C20 (n-eicosane)0.15

2. Crude feed by mass

  1. Material Stream Crude: 100 °F, 30 psia, mass flow 238,100 lb/hr (30 kg/s). On the keypad you can pick kg/s on the unit row and type 30.
  2. On the Composition page tap Edit…, switch the basis to Mass Fractions and enter the fractions above.

3. Pump

Pump P-100 from Crude to Discharge. Give Discharge 800 psia. Keep the 75 % efficiency.

4. Pipe segment

  1. Place a Pipe Segment from Discharge to Delivered.
  2. Open Rating › Sizing and tap Append Segment. For the new pipe segment enter:
    • Length 30,000 m
    • Elevation change +60 m
    • Outer diameter 0.2731 m and inner diameter 0.2545 m (10-inch). Tip: tap Outer Diameter to pick 10 inch from the pipe schedule instead of typing it.
    • Material Mild Steel
    • Increments 10
  3. Open Rating › Heat Transfer, choose Heat Loss and enter 0.

5. Questions

  1. Arrival pressure. What is the pressure of Delivered? About half the drop is lifting the oil 60 m; the rest is friction.
  2. Pump power. What power does the pump need?

Expected results

ObjectValueResult
P-100Power389.7 hp
DischargeTemperature102.7 °F
PIPE-100Pressure drop131.3 psi
DeliveredPressure668.7 psia
DeliveredTemperature103.7 °F

Of the 131 psi drop, the climb accounts for about 63 psi. The pump and the hydraulics have been checked by hand calculation.

Try next

  • Open Performance › Profiles on the pipe and plot the pressure along the line.
  • Give Delivered a pressure and leave one input empty to let the pipe calculate it (see Pipe Segment).
  • Continue with JT dew point control.