Crude oil pipeline
Pump stabilised crude into a 30 km, 10-inch line that climbs 60 m, and find the arrival pressure and pump power. Introduces mass fractions, the pump and the pipe segment.
About 25 minutes. Skills: mass fractions, pump, pipe segment, hydraulics. In the app: Start page › Oil & gas exercises › Crude oil pipeline. The finished case is Crude pipeline under Oil & gas starter cases.

1. Start a new case and set up the fluid
Tap New case. Add the eight components below, keep Peng-Robinson, and tap Simulation.
| Component | Mass fraction | Component | Mass fraction |
|---|---|---|---|
| n-Pentane | 0.03 | n-Decane | 0.18 |
| n-Hexane | 0.06 | n-C12 (n-dodecane) | 0.16 |
| n-Heptane | 0.10 | n-C16 (n-hexadecane) | 0.20 |
| n-Octane | 0.12 | n-C20 (n-eicosane) | 0.15 |
2. Crude feed by mass
- Material Stream Crude: 100 °F, 30 psia, mass flow 238,100 lb/hr (30 kg/s). On the keypad you can pick kg/s on the unit row and type 30.
- On the Composition page tap Edit…, switch the basis to Mass Fractions and enter the fractions above.
3. Pump
Pump P-100 from Crude to Discharge. Give Discharge 800 psia. Keep the 75 % efficiency.
4. Pipe segment
- Place a Pipe Segment from Discharge to Delivered.
- Open Rating › Sizing and tap Append Segment. For the new pipe segment enter:
- Length 30,000 m
- Elevation change +60 m
- Outer diameter 0.2731 m and inner diameter 0.2545 m (10-inch). Tip: tap Outer Diameter to pick 10 inch from the pipe schedule instead of typing it.
- Material Mild Steel
- Increments 10
- Open Rating › Heat Transfer, choose Heat Loss and enter 0.
5. Questions
- Arrival pressure. What is the pressure of Delivered? About half the drop is lifting the oil 60 m; the rest is friction.
- Pump power. What power does the pump need?
Expected results
| Object | Value | Result |
|---|---|---|
| P-100 | Power | 389.7 hp |
| Discharge | Temperature | 102.7 °F |
| PIPE-100 | Pressure drop | 131.3 psi |
| Delivered | Pressure | 668.7 psia |
| Delivered | Temperature | 103.7 °F |
Of the 131 psi drop, the climb accounts for about 63 psi. The pump and the hydraulics have been checked by hand calculation.
Try next
- Open Performance › Profiles on the pipe and plot the pressure along the line.
- Give Delivered a pressure and leave one input empty to let the pipe calculate it (see Pipe Segment).
- Continue with JT dew point control.