Docs › Tutorials

Stage separation

Stabilise oil through HP, MP and LP separators and a stock tank. Each valve flashes gas off the oil, and the oil shrinks and cools at every stage.

About 30 minutes. Skills: separators in series, valves, oil shrinkage. In the app: Start page › Oil & gas exercises › Stage separation. The finished case is under Oil & gas starter cases.

The finished stage separation case: HP Sep, MP Sep, LP Sep and Stock Tank with valves between them

1. Start a new case

On the Start page, tap New case.

2. Set up the fluid

Same fluid as the three-phase separator:

  1. Add the 15 components in the table below. Type part of a name in the search box (for example dec for n-Decane, C16 for n-C16) and tap +.
  2. Under Fluid Packages keep Peng-Robinson.
  3. On the package's StabTest tab, tick Liquid-liquid split (full VLLE), so the feed itself flashes to gas, oil and water.
  4. Tap Simulation.
ComponentMole fractionComponentMole fraction
Nitrogen0.005n-Pentane0.015
CO20.015n-Hexane0.03
Methane0.35n-Heptane0.05
Ethane0.07n-Octane0.05
Propane0.05n-Decane0.06
i-Butane0.015n-C16 (n-hexadecane)0.04
n-Butane0.025H2O0.213
i-Pentane0.012

3. Add the wellstream

Place a Material Stream named Wellstream: 180 °F, 1000 psia, 2000 lbmole/hr, with the mole fractions above.

4. HP separator

Place a 3-Phase Separator named HP Sep. Wellstream in; outlets HP Gas, HP Oil and Produced Water.

5. Let the oil down to 250 psia

  1. Place a Valve with HP Oil as its inlet and a new outlet MP Feed. Give MP Feed a pressure of 250 psia. The valve flashes gas out of the oil: watch MP Feed's vapour fraction.
  2. Add a Separator named MP Sep on MP Feed, with outlets MP Gas and MP Oil.

6. LP separator at 60 psia

Repeat: a valve from MP Oil to LP Feed at 60 psia, and a Separator LP Sep with outlets LP Gas and LP Oil.

7. Stock tank at 14.7 psia

Last stage: a valve from LP Oil to Tank Feed at 14.7 psia, and a Separator Stock Tank with outlets Tank Vapour and Stabilised Oil.

Tip: copy a valve and separator pair with Copy selected and Paste, then reconnect and rename the copies.

8. Questions

  1. Stabilised oil. What is the molar flow of Stabilised Oil? Compare it with HP Oil: the difference is gas released on the way down.
  2. Stock tank temperature. What temperature does the oil reach in the stock tank? Each flash takes heat from the oil to boil off gas, so every stage is colder than the last.

Expected results

StreamValueResult
HP GasMolar flow705.9 lbmole/hr
HP OilMolar flow877.7 lbmole/hr
Produced WaterMolar flow416.3 lbmole/hr
MP FeedTemperature168.7 °F
MP GasMolar flow244.8 lbmole/hr
LP FeedTemperature158.5 °F
LP GasMolar flow85.7 lbmole/hr
Tank FeedTemperature144.2 °F
Tank VapourMolar flow63.5 lbmole/hr
Stabilised OilMolar flow483.6 lbmole/hr
Stabilised OilMass flow62217 lb/hr

So HP oil shrinks from 877.7 to 483.6 lbmole/hr on its way to the stock tank, which it reaches at 144.2 °F.

Try next

  • Change the MP pressure and watch the stabilised oil flow. Why does stepping the pressure down in stages keep more liquid than one big flash?