Three-phase separator
Split a wellstream into gas, oil and produced water in one vessel. Teaches the liquid-liquid split and the 3-Phase Separator.
About 20 minutes. Skills: wellstream, liquid-liquid split, 3-Phase Separator. In the app: Start page › Oil & gas exercises › Three-phase separator. The finished case is under Oil & gas starter cases.

1. Start a new case
On the Start page, tap New case.
2. Set up the fluid
- Add the 15 components in the table below. Type part of a name in the search box (for example
decfor n-Decane,C16for n-C16) and tap +. - Under Fluid Packages keep Peng-Robinson.
- On the package's StabTest tab, tick Liquid-liquid split (full VLLE), so the feed itself flashes to gas, oil and water.
- Tap Simulation.
| Component | Mole fraction | Component | Mole fraction |
|---|---|---|---|
| Nitrogen | 0.005 | n-Pentane | 0.015 |
| CO2 | 0.015 | n-Hexane | 0.03 |
| Methane | 0.35 | n-Heptane | 0.05 |
| Ethane | 0.07 | n-Octane | 0.05 |
| Propane | 0.05 | n-Decane | 0.06 |
| i-Butane | 0.015 | n-C16 (n-hexadecane) | 0.04 |
| n-Butane | 0.025 | H2O | 0.213 |
| i-Pentane | 0.012 |
3. Add the wellstream
Place a Material Stream, rename it Wellstream (tap its name on the Conditions page) and enter:
- Temperature 150 °F
- Pressure 300 psia
- Molar Flow 2000 lbmole/hr
- The mole fractions in the table above (Composition › Edit…). They must add up to 1.
4. Add a 3-phase separator
Place a 3-Phase Separator. Connect Wellstream as its inlet and create new streams Gas (Vapour), Oil (Liquid, the light liquid) and Water (Water, the heavy liquid). Use << Type a name >> in each picker to name them as you create them.
The vessel needs no specification: it flashes the feed at its own temperature and pressure.
5. Questions
- Gas rate. Open the gas outlet. What is its molar flow?
- Produced water. Open the water outlet. What is its molar flow? Compare it with the water in the wellstream (0.213 × 2000 lbmole/hr). Almost all the water leaves here; a little stays dissolved in the gas and oil.
Expected results
What Zalosim gives with the inputs above (Peng-Robinson, Field units):
| Stream | Value | Result |
|---|---|---|
| Wellstream | Vapour fraction | 0.4726 |
| Gas | Molar flow | 945.3 lbmole/hr |
| Gas | Mass flow | 22546 lb/hr |
| Oil | Molar flow | 641.5 lbmole/hr |
| Oil | Mass flow | 69483 lb/hr |
| Water | Molar flow | 413.1 lbmole/hr |
| Gas | Temperature | 150.0 °F |
| Gas | H2O mole fraction | 0.01212 |
| Oil | H2O mole fraction | 0.002192 |
Try next
- Untick Liquid-liquid split on the StabTest tab and read the separator's warning.
- Continue with Stage separation, which uses the same wellstream.